Press Fit Tolerance: Interference Fit, Slip Fit, and Transition Fit for CNC Parts

Press Fit Tolerance Guide | Interference & Slip Fit CNC | VNcontX
Precision Machining — Tolerance Guide

Press Fit Tolerance: Interference Fit, Slip Fit, and Transition Fit for CNC Parts

Press fit tolerance determines whether two mating parts assemble correctly, hold load, and survive service. Get the interference too small and the joint slips under torque. Go too large and the bore cracks during assembly or the shaft seizes before it’s seated. Neither outcome is fixable once parts are machined.

This guide covers the three main fit categories — interference fit, transition fit, and clearance (slip) fit — with ISO 286 tolerance codes, a practical reference chart for common shaft/bore sizes, and the machining tolerances required to hold each fit reliably. If you’re sourcing CNC machining from Vietnam or another overseas facility, the last section addresses what to verify before you approve first articles.

Gloved hands aligning precision CNC machined steel shaft into bore housing — press fit tolerance assembly at VNcontX workshop Vietnam
±0.005mm Standard Tolerance
±0.003mm Precision Tolerance
Cpk ≥ 1.67 Process Capability
100% CMM First Article Inspection

The Three Fit Types — What Each One Means for Assembly

ISO 286 classifies fits by the relationship between the shaft upper deviation and the bore lower deviation. The system uses letter codes (uppercase for hole, lowercase for shaft) paired with a tolerance grade number (IT grade). Here is how the three categories behave in practice:

Interference Fit Press Fit

The shaft is larger than the bore across the entire tolerance range. Assembly requires a hydraulic press or thermal expansion (heat the bore, chill the shaft). The resulting joint transfers load through friction — no key or fastener needed.

Typical ISO codes: H7/p6, H7/r6, H7/s6. Applications: bearing races, gear hubs, sleeve bushings, motor armatures.

Transition Fit

The shaft and bore tolerances overlap. Some part pairs from the same batch will be a light press fit; others will have a small clearance. Assembly is possible by hand but may require a mallet.

Typical ISO codes: H7/k6, H7/m6, H7/n6. Applications: dowel pins, locating bushings, encoder disks requiring precise centering.

Clearance Fit Slip Fit & Tolerance for Slip Fit

The bore is always larger than the shaft across the full tolerance range. The parts slide together by hand. Clearance determines how much the shaft can move radially — critical for bearing housings, sliding shafts, and rotating fits. For slow-speed rotating shafts, H7/f7 is standard; for precision rotating fits, H7/g6 is preferred.

Typical ISO codes: H7/f7, H7/g6, H7/h6. Applications: linear guides, pivot shafts, replaceable wear inserts, rotating journal bearings. In VNcontX’s CNC machining Vietnam facility, slip fit bores are finish-reamed and measured with Mitutoyo bore gauges before release.

Hole-basis vs. shaft-basis: Most designs use the hole-basis system (H tolerance for the bore, varied shaft code) because boring and reaming are harder to adjust mid-run than turning. Shaft-basis (h shaft, varied bore) is used when the shaft is a ground standard stock diameter.

Press Fit Tolerance Chart: ISO 286 Shaft & Bore Size Reference

The values below follow ISO 286 for hole-basis H7 bore paired with common shaft tolerance grades. All values in micrometers (μm). Positive = shaft larger than bore (interference); negative = shaft smaller (clearance).

Nominal Diameter H7 Bore (μm) p6 Shaft — Press Fit k6 Shaft — Transition h6 Shaft — Slip Fit f7 Shaft — Free Fit
3–6 mm +12 / 0 +20 / +12 +9 / +1 0 / −8 −10 / −22
6–10 mm +15 / 0 +24 / +15 +10 / +1 0 / −9 −13 / −28
10–18 mm +18 / 0 +29 / +18 +12 / +1 0 / −11 −16 / −34
18–30 mm +21 / 0 +35 / +22 +15 / +2 0 / −13 −20 / −41
30–50 mm +25 / 0 +42 / +26 +18 / +2 0 / −16 −25 / −50
50–80 mm +30 / 0 +51 / +32 +21 / +2 0 / −19 −30 / −60
80–120 mm +35 / 0 +59 / +37 +25 / +3 0 / −22 −36 / −71

Values derived from ISO 286-1:2010. Shaft deviation shown as upper/lower limit relative to nominal diameter. Verify against your drawing callout — some legacy drawings use ANSI B4.1 inch-series limits.

How to read this table: For a 25mm shaft with an H7/p6 press fit, the bore is +21μm to 0μm above nominal; the shaft is +35μm to +22μm above nominal. Minimum interference = 22 − 21 = 1μm. Maximum interference = 35 − 0 = 35μm. The machinist must hold both shaft and bore within their respective bands to keep interference within this 1–35μm range.
Gloved hands measuring CNC machined aluminum bore diameter with Mitutoyo digital gauge on granite surface plate — press fit tolerance verification VNcontX Vietnam

Press Fit Tolerance Calculator — Quick Estimation Method

For a fast interference check without dedicated software, use the following approach: δ = D × k, where δ is target interference, D is nominal diameter, and k is a material-based constant. For steel/steel: k = 0.0008–0.001 (H7/p6 range). For aluminum bore / steel shaft: k = 0.0004–0.0006 to stay below yield.

Example: 30mm steel/steel press fit → δ = 30 × 0.001 = 0.030mm (30μm) maximum interference. Cross-reference against the H7/p6 row in the table above (max interference for 18–30mm = 35μm) — this falls within the p6 band, confirming the fit selection.

For full Lamé equation calculation with hoop stress and press force output, Roymech’s interference fit calculator is a reliable free tool. Input your bore diameter, engagement length, material moduli, and target interference to get contact pressure and required press force.

What Machining Tolerances Are Actually Required

A press fit tolerance callout on a drawing is not the same as a machining tolerance. The fit tolerance is the allowable range of shaft-to-bore size difference. The machining tolerance is the allowable variation in each individual part — and it must be tight enough that every part in the batch lands within the fit zone.

H7/p6 Press Fit — Machining Requirements

For a 25mm H7/p6 press fit, the bore tolerance band is 21μm and the shaft tolerance band is 13μm. To hold Cpk ≥ 1.33 (minimum acceptable process capability), your 6-sigma spread must fit within the tolerance band.

Required machine capability: ±0.005mm (5μm) or better on bore diameter. Boring on a machining center or dedicated jig boring machine. Finish reaming is preferred for H7 bores above 8mm.

Shaft Turned to p6 or k6 — Machining Requirements

p6 on a 25mm shaft requires the OD to land between +22μm and +35μm above nominal — a 13μm band. k6 is 15μm to 2μm above nominal — a 13μm band with zero interference on the low side.

Required machine capability: CNC turning with CBN insert finish pass. Post-process OD measurement with Mitutoyo micrometer or on-machine gauging. Cylindricity ≤ 3μm to prevent edge loading.

At VNcontX, press fit bores are finished by boring with Sandvik TCMT inserts, followed by a reaming pass where the fit grade requires it. Shaft ODs are finish-turned on a Mazak QT turning center with a final tool-radius compensation pass. Every first article receives a full CMM report (Zeiss Contura) documenting bore diameter, shaft OD, cylindricity, and perpendicularity of the bore axis. See CNC machining services for machine capability details.

Production Example — Bearing Housing Press Fit
PartAluminum 6061-T6 bearing housing, 45mm bore
Fit requirementH7/p6 — press fit for a 45mm OD bearing outer race
Bore tolerance (H7)+25μm / 0 above nominal (45.000 to 45.025mm)
Bearing OD (p6)+42μm / +26μm above nominal (45.026 to 45.042mm)
ProcessRough bore → semi-finish bore → ream H7 → CMM check before release
CMM resultBore: 45.014mm ± 0.003mm across 24-piece batch. Cpk = 1.82.

Numbers from production run at VNcontX Bình Chánh facility. Client details withheld per NDA.

How Material Affects Press Fit Tolerance Selection

The interference required to develop a given retention force depends on the elastic modulus and yield strength of both mating materials. An interference that works in steel-on-steel will cause bore yielding if applied to an aluminum housing with a steel shaft.

Steel / Steel

Full ISO p6, r6, s6 interference is available. Retention force scales with interference — s6 develops roughly 2.5× the retention of p6 for the same bore diameter. Assembly requires a hydraulic press and lubricant (molybdenum disulfide or light oil). Calculate hoop stress at maximum interference to confirm bore wall thickness is adequate.

Aluminum Housing / Steel Shaft

Aluminum yield strength (6061-T6: 276 MPa) limits maximum interference. H7/p6 is generally safe for bore diameters up to 50mm in 6061-T6 with a wall-to-bore ratio above 1.5. At larger diameters or thinner walls, use H7/n6 (transition) and verify retention force by calculation. Thermal cycling between −40°C and +120°C will modulate interference — check net interference at operating temperature extremes.

Stainless Steel (303/304) Housing

Similar modulus to carbon steel — standard H7/p6 interference applies. Note that 303/304 work-hardens rapidly during boring; use sharp, positive-rake inserts and do not dwell on the bore wall.

Galling risk: stainless-on-stainless press fits are prone to cold welding (galling) during assembly if surfaces are dry. Always use anti-seize (molybdenum disulfide or nickel-based) during press assembly of stainless/stainless pairs, or specify a dissimilar material pairing where possible.

Plastic / Composite Housing

POM (Delrin) and PEEK have low elastic modulus compared to metal. Light press fits (H7/n6 or H7/m6) are more appropriate; heavy interference causes cold flow over time, reducing retention. Thermal expansion coefficient of plastics is 5–10× higher than steel — interference specs must account for operating temperature range.

Shrink Fit vs Press Fit — When to Use Thermal Assembly

When interference exceeds what a hydraulic press can safely apply without galling or bore damage — typically H7/s6, H7/u6, or above — thermal expansion assembly is the standard method. The bore is heated to 150–250°C (expanding it by approximately 0.012mm per 100mm diameter per 100°C for steel), the shaft is chilled to −40 to −80°C with dry ice or liquid nitrogen, and the parts are assembled by hand within the thermal window.

Shrink fits develop contact pressures 2–4× higher than equivalent press fits at the same nominal interference, because there is no frictional drag during assembly — the full interference engages uniformly as the temperatures equalize. Use shrink fit (H7/s6 or heavier) for permanent gear/hub joints, motor armatures, and bearing races in high-vibration applications. VNcontX machines shrink fit bores to H7 with the same ±0.005mm capability as press fit bores; confirm the assembly method on your drawing or during DFM review.

What to Verify When Sourcing Press Fit Parts from an Overseas CNC Supplier

Press fit tolerance failures from overseas suppliers typically fall into four categories. Identifying which applies before first article sign-off avoids rework, redesign, or full scrapped production batches. At VNcontX’s CNC machining Vietnam facility, all four points below are addressed as standard in the FAI process.

1. Process capability not verified before production

A machinist can hold ±0.005mm as a one-off but cannot guarantee every part in a 500-piece run lands within specification without documented Cpk. Request Cpk data from a 30-piece pilot run before approving a full production order. Minimum acceptable Cpk for press fit dimensions: 1.33 for general use, 1.67 for critical retention joints.

2. Measurement equipment mismatch

H7 bores in the 10–50mm range require an internal bore gauge or CMM measurement — not a simple go/no-go plug gauge if you need to know the actual size. Verify the supplier measures bore diameter with a calibrated Mitutoyo or Zeiss CMM, and that the measurement report includes actual values, not just pass/fail check marks.

3. Surface finish on bore wall not specified

A bored surface at Ra 3.2μm will develop less retention than a reamed surface at Ra 0.8μm for the same interference — because effective contact area is lower. Press fit bores should specify Ra ≤ 0.8μm on the drawing. At VNcontX, H7 press fit bores receive a reaming pass as standard; Ra is verified with a Mitutoyo SJ-210 profilometer at FAI.

4. Drawing tolerance interpreted incorrectly

If your drawing calls out the fit as a bilateral tolerance (e.g., 25.030 +0.000/−0.013) rather than an ISO code, confirm the supplier interprets this as a maximum-material / least-material condition correctly. Common error: the machinist targets the center of the tolerance band regardless of whether the fit requires a bias toward one end. This matters most on transition fit dimensions where nominal interference is near zero.

Press Fit Tolerance — Frequently Asked Questions

What is the difference between a press fit and an interference fit?
The terms are often used interchangeably. Strictly speaking, “interference fit” describes any condition where shaft diameter exceeds bore diameter across the full tolerance range. “Press fit” describes the assembly method — the shaft is forced into the bore using press force rather than hand assembly. All press fits are interference fits, but the inverse is not always true: a very light interference fit (H7/n6 boundary condition) may be assembled with a mallet rather than a hydraulic press, and some engineers still call this a press fit informally.
Can a press fit replace a key or set screw for torque transmission?
Yes, within load limits. Retention torque from a press fit is proportional to contact pressure, which is proportional to interference and bore length. For a 25mm H7/p6 steel-on-steel fit with 20mm engagement length, retention torque is approximately 150–300 N·m depending on surface finish and lubrication condition at assembly. If your design requires disassembly at any point, factor in that repeated press/pull cycles reduce effective interference — the bore expands slightly each cycle from elastic-plastic deformation. Use a shrink fit (H7/s6 or H7/u6) for permanent no-disassembly joints requiring high torque.
What tolerance for slip fit when the shaft must rotate inside the bore?
For slow-speed rotation or oscillation with a plain (non-rolling) bearing, H7/f7 gives 20–80μm clearance across the size range — adequate for most sliding shaft applications. For higher speeds with hydrodynamic lubrication, H7/g6 (tighter clearance, 10–40μm range) is preferred to maintain oil film without excessive shaft whip. For precision rotating shafts in machine tool spindles, H6/g5 or H5/h4 is typical. Specify the clearance explicitly on the drawing rather than relying on the ISO code alone; this prevents misinterpretation by the machining supplier.
Does anodizing affect press fit tolerance on aluminum bores?
Yes — significantly. Type II anodize (decorative/protective) adds approximately 8–15μm per surface. A bore anodized after machining will have its effective diameter reduced by 16–30μm total (anodize grows inward for bores). Type III hard anodize adds 25–75μm per surface — a 50–150μm reduction in bore diameter. If the bore receives anodize after machining, the machined bore must be oversized by the expected anodize buildup to achieve the design fit. Either machine the bore after anodizing (using carbide tooling, as hard anodize is abrasive), or specify the bore as a masked area. At VNcontX, press fit bores on anodized aluminum parts are either masked during anodize or finish-bored post-anodize — call this out on your drawing or discuss during DFM review.
How do I calculate the press force required for assembly?
The Lamé equation for thick-walled cylinders gives contact pressure P from interference δ, moduli E₁/E₂, Poisson ratios ν₁/ν₂, and wall geometry. Press force F = P × π × d × L × μ, where d is bore diameter, L is engagement length, and μ is the friction coefficient (0.12 for steel/steel dry, 0.08 with light oil). For quick estimation: a 25mm H7/p6 steel/steel fit with 25mm engagement requires roughly 8–18 kN press force. If you send your drawing with bore diameter, engagement length, material callout, and interference range, our engineering team will provide a press force estimate during DFM review at no charge.
Precision CNC Machining Vietnam

Send Your Drawing. Get a CMM-Verified First Article.

Press fit bores to H7. Shaft ODs to p6, k6, or h6. ±0.005mm standard — ±0.003mm precision. Cpk ≥ 1.67. 100% FAI with CMM report. ISO 9001:2015 certified. Lead time 7–12 days standard.

Request a Technical Quote → Talk to an Engineer →

Email: duc.nguyen@vncontx.com  |